Home  |  News  |  Technical Info  |  Contact  |  Distributors  |  How to find us  |  Support    |    Search

Analogue Signalling Converter - ASC300

ASC300 Analogue Signalling Converter

Conversions

GEN-GEN SSAC15A
Magneto Signalling or manual 2280Hz
ASC300 ASC300
Manual E&M SSDC5A SSAC15A Manual 2280Hz Manual E&M SSDC5A GEN-GEN

The Kenton Research analogue signalling converter ASC300 provides conversion of a single circuit from gen-gen (magneto) signalling to SSAC15A or manual 2280Hz signalling or to 2-wire audio plus E & M with manual or SSDC5A signalling. The unit can also convert from SSAC15A or manual 2280Hz signalling to SSDC5A or manual E & M signalling with 2-wire or 4-wire audio. The converter features simple installation and setup with a multicoder for major configuration settings and single links for other options. An internal overload protected source of ring current is incorporated and the unit is fitted with dc input current limiting. The ASC300 E & M leads physically interface to UK SSDC5A equipment and they can be link configured to operate with North American type 1 and type 2 standards. The ASC300RM is a plug in 48V dc powered extended eurocard module for mounting in the 19 inch mounting shelf 12E7K or equivalent BABT approved enclosure. The ASC300SA is a wall mounted unit mains powered from the supplied PU246D plug top power supply.

APPROVED FOR CONNECTION TO THE TELECOMMUNICATIONS NETWORK

ASC300 SPECIFICATIONS

GEN INTERFACE Port 600 ohm 2-wire
    maximum level to line 0dBm
    4dB nominal loss to 2280Hz port
    3dB nominal loss to E & M port 2-wire audio      
  Signalling detector sensitivity 20v RMS 17-25 Hz
    call signal 65v RMS @ 25 Hz nominal
E & M INTERFACE Audio 600 ohm link selectable 2 or 4-wire
    maximum level to line 0dBm
    4-wire audio 0dB nominal loss to 2280Hz port
    2-wire audio 4dB nominal loss to 2280Hz port
  Signalling link selectable for SSDC5A or manual operation
    idle - open circuit
    signal - earth via 1200R/1uF NSF or direct
    SB (Signal battery) connected to -48V or open
    SG (Signal ground) connected to 0V or open
2280Hz INTERFACE Line Circuit 600 ohm 4-wire 4dB gain
    provision to increase gain by 4dB for direct connection
    audio output level -4dBm nominal
    audio input level 0dBm nominal
  Signalling link selectable for SSAC15A or manual operation
    output tone frequency 2280 +/- 1Hz
    output tone leve -24 / -14 dBm +/- 1dB
    detector operate level -3 to -29dBm
    AC15A - tone on idle both directions
    manual - tone on during signalling
PHYSICAL   ASC300RM ASC300SA
  Power -43 to -57V dc @ 140 mA 220 to 250V 50-60 Hz
  Size 100 x 220 x 35.5 mm 160 x 135 x 45mm
  Weight 0.26kg 0.5kg
  Connector DIN41612 male row a fitted insulation displacement IDC
  Mounting 11024B 3U 19 inch shelf stand alone wall mounted
APPROVAL BABT NS/4271/2/T/605092 NS/4271/2/T/605091